© tetronik GmbH. All rights reserved.
© tetronik GmbH. All rights reserved.
Personal Emergency Signal Systems (German abbreviation: PNA) in keeping with DIN V VDE V 0825-1 are systems that activate and transmit both deliberate and automatic distress signals in emergency situations. They ensure the protection of persons who work alone (so-called "lone workers") in hazardous workplaces, and they do so in full conformity with the German DGUV Rule 112-139.
Occupational safety is subject to strict legal regulations. In accordance with the DGUV (German Social Accident Insurance), people working alone out of earshot and sight of others must be protected by a Personal Emergency Signal System for certain hazardous activities.
DAKS-PNA is certified by the German Social Accident Insurance (DGUV) as such a Personal Emergency Signal System (PNA for short) in accordance with DIN VDE V 0825-1. The system enables the triggering, transmission and location of deliberate and automatic alarms and is used to protect people working alone in hazardous situations in accordance with DGUV regulations.
Excerpt from DGUV Regulation 1 (“Principles of Prevention”)
§8 – Hazardous work
(2) If hazardous work is carried out by one person alone, the employer must ensure that appropriate technical or organizational measures are taken to protect the person in addition to the general protective measures.
Excerpt from DGUV Rule 100-001
[...] Technical measures include, for example, the use of suitable personal emergency signal systems. Further information can be found in DGUV Rule 112-139 “Use of personal emergency signal systems.” [...]
Alarm server= Emergency Call Response Center as defined by the DGUV rule | |
Telephone/DECT system | Mitel Unify OpenScape 4000 (telephone system) Mitel Unify OpenScape Cordless IP V2 (OSCIP V2) * Gigaset N870 IP PRO * * These options can be connected to any existing telephone system or used completely independently. |
DECT mobile devices= Personal Emergency Signal Device with Voice Function as defined by the DGUV rule | Mitel Unify OpenStage M3 Plus or M3 Ex Plus * * Device can be used in both Mitel Unify and Gigaset infrastructures. |
Alarm server= Emergency Call Response Center as defined by the DGUV rule | |
DECT system | Spectralink DECT Server 8000 Spectralink IP-DECT Server 6500 Spectralink VIP-DECT Server ONE |
DECT mobile devices= Personal Emergency Signal Device with Voice Function as defined by the DGUV Rule | Spectralink 7642 and S37 |
DAKS-PNA P8SL can be connected to any existing telephone system or used completely independently.
© tetronik GmbH. All rights reserved.